Orion-system Water Source Heat Pump X Module User Manual

Browse online or download User Manual for Hardware Orion-system Water Source Heat Pump X Module. Orion System Water Source Heat Pump X Module User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 32
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Water Source
Heat Pump X Module
Field Technical Guide
WATTMASTER CONTROLS
Y 102374 REV 0S
MADE IN USA
M
ENTER
UP
DOWN
ALARM
MENU
OE334-26-WSHPX-A WSHP-X MODULE AAON NO.: V18330
WattMaster Label
#SW000054
Rev.: 1A
E-BUS
CONNECT
E-BUS
CONNECT
+24 VAC
GND
www.orioncontrols.com
www.aaon.com
BIN 1
BIN 2
BIN 3
BIN 4
BIN 5
BIN 6
BIN 7
COM
- COMP. A1 EN.
- HEAT ENABLE
- COMP. A2 EN.
- WATER POF
- COMP. B1 EN.
- WATER POF
- COMP. B2 EN.
- COMMON
T1
T2
GND
- LEAVING WATER TEMP A
- GROUND
- LEAVING WATER TEMP B
AO1
A2O
STAGE 1- COMP. A1/B1-
STAGE 2 - COMP. A2/B2
DIGITAL COMP. A1, A2, B1, B2
RELAY CONTACT RATING
IS 1 AMP MAX @ 24 VAC
COMP. A2 ENABLE
COMP. A1 ENABLE
R1
R2
R3
R4
R5
RC
RELAY COMMON
COMP. B1 ENABLE
COMP. B2 ENABLE
ALARM OUTPUT
CONNECT TO CNTLR C2 TERM.
+5V
PRES
GND
+5V
PRES
GND
SUCT. PR. SENSOR
PRES 1=A1, PRES 2=A2
PRES 3=B1, PRES 4=B2
NOT USED
PRES 1=A1, PRES 2=A2
PRES 3=B1, PRES 4=B2
+5 NOT USED, PRES TO P6 & GND TO P5
+5 TO RED, PRES TO WHT & GND TO BLK
DIGITAL COMRESSORS
NON-DIGITAL COMPRESSORS
Factory Packaged Controls
Page view 0
1 2 3 4 5 6 ... 31 32

Summary of Contents

Page 1 - Field Technical Guide

Water Source Heat Pump X ModuleField Technical GuideWATTMASTER CONTROLSY 102374 REV 0SMADE IN USAMENTERUPDOWNALARMMENUOE334-26-WSHPX-A WSHP-X MODULE

Page 2 - Table of Contents

WSHP-X ModuleTechnical Guide10Installation & WiringVCM-X WSHP E-BUS or SA E-BUS Controller to WSHP-X Module Wiring for Single Water CircuitThe WSH

Page 3 - Module Overview

Technical Guide WSHP-X Module 11Line VoltageAll Comm Loop Wiring IsStraight Thru24VACGNDLoca

Page 4

WSHP-X ModuleTechnical Guide12Installation & WiringVCM-X WSHP or SA Controller to WSHP-X Module Wiring for Dual Water CircuitThe VCM-X WSHP Contro

Page 5

Technical Guide WSHP-X Module 13WATTMASTER CONTROLSY 102374 REV 0SMADE IN USAWARNING!!Obser

Page 6

WSHP-X ModuleTechnical Guide14Installation and WiringVCM-X WSHP E-BUS or SA E-BUS Controller to WSHP-X Module Wiring for Dual Water CircuitThe WSHP-X

Page 7

Technical Guide WSHP-X Module 15Line VoltageAll Comm Loop Wiring IsStraight Thru24VACGNDLoca

Page 8

WSHP-X ModuleTechnical Guide16Start-Up & CommissioningGeneralIn order to have a trouble free start-up, it is important to follow a few simple proc

Page 9

Technical Guide WSHP-X Module 17Sequence of OperationTable 2: WSHP-X Module Inputs & Ou

Page 10 - Installation & Wiring

WSHP-X ModuleTechnical Guide18Sequence of OperationStand-Alone Input Commands Compressor On/OffA 24 volt signal to Binary Inputs #1-4 initiates each C

Page 11

Technical Guide WSHP-X Module 19Sequence of OperationModes of OperationNOTE: See the Unit C

Page 12 - Water Circuit

Table of ContentsOVERVIEW ...

Page 13

WSHP-X ModuleTechnical Guide20Navigation KeysLCD Display Screen & Navigation KeysThe WSHP-X Controller allows you to make confi guration changes

Page 14 - Installation and Wiring

Technical Guide WSHP-X Module 21Main Screens MapRefer to the following map when navigating t

Page 15

WSHP-X ModuleTechnical Guide22Alarm Screens Alarm ScreensRefer to the following map when viewing the Alarm Screens. These screens will display automat

Page 16 - Start-Up & Commissioning

Technical Guide WSHP-X Module 23System Status A ScreensRefer to the following map when navig

Page 17 - Sequence of Operation

WSHP-X ModuleTechnical Guide24System Status B Screens SYSTEM B, COMPRESSOR 2This screen displays the current status of the B2 Compressor. OFFPENDING:

Page 18

Technical Guide WSHP-X Module 25Setpoint ScreensSetpoint Status ScreensRefer to the followin

Page 19 - Modes of Operation

WSHP-X ModuleTechnical Guide26TroubleshootingSafety Monitoring for Single Water CircuitProof of Flow1. If there is a call for a compressor and there

Page 20 - Navigation Keys

Technical Guide WSHP-X Module 27TroubleshootingSafety Monitoring for Dual Water CircuitProof

Page 21

WSHP-X ModuleTechnical Guide28 Thermistor Sensor Testing InstructionsUse the resistance column to check the thermistor sensor while discon-nected fro

Page 22 - Alarm Screens

Technical Guide WSHP-X Module 29OE275-01 Suction Pressure Transducer Testing for R-22 &

Page 23 - System Status A Screens

Technical Guide WSHP-X Module 3OverviewThe OE334-26-WSHPX-A Water Source Heat Pump X (WSHP-X

Page 24 - System Status B Screens

WSHP-X ModuleTechnical Guide30TroubleshootingUsing LEDs to Verify OperationThe WSHP-X Module is equipped with LEDs that can be used to verify operatio

Page 25 - Setpoint Screens

Technical Guide WSHP-X Module 31TroubleshootingSuction Pressure Transducer LEDs“PRES 1-4”

Page 26 - Troubleshooting

2425 So. Yukon Ave • Tulsa, OK 74107-2728Ph: (918) 583-2266 • Fax: (918) 583-6094AAON® Manual Part No. V23560 WattMaster Manual Form No: AA-WSHPX-FIE

Page 27

WSHP-X ModuleTechnical Guide4Installation & WiringPower SupplyThe WSHP-X Module requires a 24 VAC power connection with an appropriate VA rating.

Page 28

Technical Guide WSHP-X Module 5Important Wiring ConsiderationsPlease read carefully and appl

Page 29

WSHP-X ModuleTechnical Guide6Figure 4: Water Source Heat Pump X Module as Stand-Alone for Dual Water CircuitNOTE: NORMALLYOPEN AND RATED FOR 24 VAC P

Page 30 - Operation Status LEDs

Technical Guide WSHP-X Module 7Installation & WiringE-BUS to WSHP-X Module WiringThe WSH

Page 31

WSHP-X ModuleTechnical Guide8Installation & WiringVCM-X WSHP to WSHP-X Module Wiring for Single Water CircuitThe VCM-X WSHP Controller or SA Contr

Page 32 - Manual Part No. V23560

Technical Guide WSHP-X Module 9WATTMASTER CONTROLSY 102374 REV 0SMADE IN USAWARNING!!Observ

Comments to this Manuals